At noon, an installer opens the PV disconnect next to a residential string inverter. Which conductors can still carry dangerous DC voltage?
One tap per item counts toward the score; opening the key first leaves the item unscored.
Skip ahead to the key and the reasoning
Opening the disconnect separates the inverter from the array, but the conductors between the array and the switch are still connected to the array and stay energized in daylight.
The inverter's output conductors carry alternating current from the utility side, not DC; the DC hazard sits upstream of the open switch.
The grounding electrode conductor normally sits at earth potential; it is not among the array's current-carrying circuit conductors.
An OFF handle only shows that the switch contacts are open; the wiring on the array side of the switch is still live in daylight.